Product Code: Y-2004

  Specification

Model

King Deca

Interface

Host

USB interface (Win98/ ME/ 2000/ XP)

Device

• ATA x 3 (ULTRA ATA 40 PIN)
• S-ATA x 3 (S-ATA)

Main Function (HDD Analysis)

Transfer Speed Test : Measure data transfer speed at specified commands (READ/WRITE/READ COMPARE/VERIFY) and at specified sector/block areas. Provides multiple options such as Seek Mode (increment, decrement, convergence, divergence, random, repeat), Write data methods, Buffer cache usage and error response. The result can be obtained in minimum, maximum and average (MB/Sec.) and displayed by graphing functions.

Response Time Test: Measure the data response time at specified command (READ/WRITE/READ COMPARE/VERIFY) at specified sector/block(s) area. Provides various options such as seek mode (increment, decrement, convergence, divergence, random, repeat), WRITE data methods, Buffer cash usage and error response. The result can be obtained in minimum, maximum and average (ms) with graphing functions.

Delay Block Search Test: By setting a threshold for response time (ms) the user can  identify the delayed sector/block(s) and indicate the slow block sectors in the matrix. Test can be performed at specified sector/block areas and provides various options such as Seek Mode (increment, decrement, convergence, divergence, random, repeat), Write data methods, Buffer Cache Usage and Error Response. Results can be displayed with graphing functions

Error Rate Test
: Measure and calculate error rate by WRITE/READ/COMPARE. Various conditions can be assigned for the purpose of performing the durability test.

Fixed Point Access test: Hold arm to the media surface (NO ramp load) and continue to perform the specified command for specified intervals. Various options can be assigned when performing the durability test.

ECC Correction Performance Test: Measure the error correction (ECC) capability by intentionally tampering data at bit level on the media. Calculate correction time and speed rate at various conditions assigned.

Ramp Load Test : Designed to repeat on power-on, access, and power-off cycles to understand the durability of mechanical functions of hard drive. The threshold can be set to indicate Pass/Fail with various conditions.

Main Function (HDD Management)

Serial ATA, ATA interface compatible.
FAT, NTFS file system (Win95, 98, 2000 and others).
Data Area copy & compare (FS mapping & compare).
EXT 2/3, HFS, OS9, OSX file system
  (Unix, Linux, Mac, and others).
Data Area copy & compare (E5 Mapping Copy).
Big drive compatible (MAX, 144PB-48 bit).
Copy & Bit Compare clipping capability.
Data secure deletion (DoD 5220, 22M, NSA).
Serial ATA and ATA cross copy function.
Repair (Bad sector reassignment, mask bad sectors  _where data cannot be collected)

Connectable Targets

Copy

2 (1:2)

Evaluation

3

Protection & Safety

(Primary power input) FUSE3A

Input Power

AC110V - 250V, 50/60Hz

Dimension

W380 D285 H100

Weight

4kg

Product includes

• Power cable (AC3P-2P connector) x 1
• ATA I/F cable x 3
• S-ATA I/F cable x 3
• USB cable x 1
• Custom software
• DC connector pull-out Jig
• PC cover removal Jig
• Carrying case x 1
• DC cable x 3

Top

            Products 

Personal HDD Duplicators
ShadowHD
PC-AID 
Mass Hard Drive Duplicators
King Hit (1:5) or (1:59max)
King Demi-A/AS (1:2)
Demi-UAS/UAv2 (1:1)
Hard Drive Management
King Test
King Deca
King Kesender Mini
Kesender
Kesender II
Industrial Rack System
Data Recovery Tools
King Demi-AS-F
Kesender II (with DR option)
HDD Rock

                Services                

HDD Duplication
HDD Destruction
HDD Test/Analysis
HOME